Neware CE-6004n-500V200A-IG Battery Pack Testing System, ENCE6004n500V200AIG

SKU: ENCE6004n500V200AIG

Neware CE-6004n-500V200A-IG Battery Pack Testing System, ENCE6004n500V200AIG — Four-channel Neware CE-6004n regenerative battery-pack tester rated at 500 V / 200 A, with 100 kW per channel, 400 kW total output, and 24-bit acquisition.

Need help selecting a configuration? Request a competitive quote today!

Neware CE-6004n-500V200A-IG Battery Pack Testing System, ENCE6004n500V200AIG

Product Type: High-Voltage Regenerative Battery Pack Testing System
Brand: Neware
Part Number: ENCE6004n500V200AIG

Product Introduction

The Neware CE-6004n-500V200A-IG is a four-channel regenerative tester for full battery packs used in electric vehicles and energy-storage systems. Its 500 V / 200 A architecture handles high-power charge/discharge profiles while returning discharge energy to the facility supply.

Key Features

500 V / 200 A configuration — high-voltage pack-level test capability
Four test channels — 100 kW specified output per channel
400 kW total output — industrial regenerative power platform
24-bit resolution — ±0.02% F.S. voltage and ±0.05% F.S. current accuracy
≤5 ms current response — supports drive-cycle simulation, DCIR, pulse testing, and GITT

Specification

ParameterSpecification
Part Number
  • ENCE6004n500V200AIG
Power
  • AC380V±10%, three phase, 50/60Hz, 444.4 kW
Channel Numbers
  • 4 channels

Voltage Features

  • Charge Voltage: 0-500 V
  • Discharge Voltage: 10 V ~ 500 V
  • Minimal discharge voltage: 10 V
  • Accuracy: ± 0.02% of F.S.
  • Resolution: 24 bit
Current Features
  • Output Range: 1A – 200A
  • Accuracy: ± 0.05% of F.S.
  • CV Cut-Off Current: 0200 mA
  • Resolution: 24 bit
Output Power
  • 100 kW/Channel
  • Whole machine output power: 400 kW
Time
  • Current Response Time: ≤5 ms
  • Current Conversion Time:  ≤10 ms
  • Min. Step Time: 0.1 s
Main Test Functions
  • Constant current charging/discharging (CCC/CCD)
  • Constant voltage charging/discharging (CVC/CVD)
  • Constant power charging/discharging (CPC/CPD)
  • Constant current constant voltage charging/discharging (CCCVC/CCCVD)
  • DCIR
  • Pulse Simulation Test
  • GITT
Data Record/Report
  • Recording Conditions: (a) minimum time interval: 10 ms; (b) minimum voltage interval: 1 V; (c) Minimum current interval: 0.4 A.
  • Export File Types: Excel, TXT

Applications

EV battery-pack validation, energy-storage pack cycling, regenerative load testing, drive-cycle simulation, and high-voltage production qualification.

References:

J. Li, et al., Accurate battery pack modeling for automotive applications, J. Power Source, 2013, 237, 215-228

S. Mutagekar, et al., Understanding the Li-ion battery pack degradation in the field using field-test and lab-test data, Journal of Energy Storage, 2022, 53, 105216.

Note: Browse related products in the Battery Testing Equipment category.