Neware CE-6008n-20V120A-H Battery Module Testing System, ENCE6008n20V120AH

SKU: ENCE6008n20V120AH

Neware CE-6008n-20V120A-H Battery Module Testing System, ENCE6008n20V120AH — Neware CE-6008n-20V120A-H regenerative module tester rated for 20 V / 120 A operation across 8 channels, with 24-bit acquisition and programmable high-power cycling functions.

Need help selecting a configuration? Request a competitive quote today!

Neware CE-6008n-20V120A-H Battery Module Testing System, ENCE6008n20V120AH

Product Type: Regenerative Battery Module Testing System
Brand: Neware
Part Number: ENCE6008n20V120AH

Product Introduction

The Neware CE-6008n-20V120A-H is an industrial battery module tester configured for 20 V / 120 A operation across 8 channels. It is designed for programmable, high-power charge/discharge testing in pilot-line, validation, and production environments.

Key Features

20 V / 120 A configuration — rated voltage and current for this system
8 channels — parallel test capacity specified for this model
24-bit measurement architecture — supports detailed voltage and current acquisition
Fast dynamic control — specified current response of ≤3 ms and conversion time of ≤6 ms
Regenerative test platform — supports CCC/CCD, CVC/CVD, CPC/CPD, CCCV, DCIR, pulse simulation, and GITT

Specification

ParameterSpecification
Part Number
  • ENCE6008n20V120AH
Power
  • AC380V±10%, three phase, 50/60Hz, 22.6 kW
Channel Numbers
  • 8 channels

Voltage Features

  • Charge Voltage: 0-20 V
  • Discharge Voltage: 3 V ~ 20 V
  • Minimal discharge voltage: 3 V
  • Accuracy: ± 0.1% of F.S.
  • Resolution: 24 bit
Current Features
  • Output Range: 0.6A – 120A
  • Accuracy: ± 0.05% of F.S.
  • CV Cut-Off Current: 120 mA
  • Resolution: 24 bit
Output Power
  • 2.4 kW/Channel
  • Whole machine output power: 19.2 kW
Time
  • Current Response Time: ≤3 ms
  • Current Conversion Time:  ≤6 ms
  • Min. Step Time: 0.1s
Main Test Functions
  • Constant current charging/discharging (CCC/CCD)
  • Constant voltage charging/discharging (CVC/CVD)
  • Constant power charging/discharging (CPC/CPD)
  • Constant current constant voltage charging/discharging (CCCVC/CCCVD)
  • DCIR
  • Pulse Simulation Test
  • GITT
Data Record/Report
  • Recording Conditions: (a) minimum time interval: 10 ms; (b) minimum voltage interval: 0.04 V; (c) Minimum current interval: 0.24 A.
  • Export File Types: Excel, TXT
Dimension
  • L600 mm * W800 * H1800 mm
Weight
  • ~265 kg

Applications

Battery module cycling, performance validation, dynamic load simulation, DCIR testing, and pilot- or production-line quality evaluation.

References:

J. Li, et al., Accurate battery pack modeling for automotive applications, J. Power Source, 2013, 237, 215-228

S. Mutagekar, et al., Understanding the Li-ion battery pack degradation in the field using field-test and lab-test data, Journal of Energy Storage, 2022, 53, 105216.

Note: Browse related products in the Battery Testing Equipment category.